<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15075</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: trailing edge clamps failed to lock
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check the clamp lock sensor see is it is operational. Use "tec" command from the diagnostics
to display the sensor status. If the sensor is faulty, use "set al tls 0" to bypass the sensor
and get the customer going. Arrange for field service. If the sensor is OK, test the TEC lock/unlock
mechanism by using "tec lock" or "tec unlock" and see if any motion occurs.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Click RESUME to see if the error goes away. If not, call Creo for service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty clamp unlock sensor
</Cause>
<Cause>
Faulty TEC lock/unlock mechanism.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_tls.xml</LinkAddress><LinkTitle>NVS: al tls</LinkTitle></Link>
<Link><LinkAddress>../commands/tec.xml</LinkAddress><LinkTitle>Command: tec</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:51 2008 PST
</Updated>
<Links>
</Links>
</Error>